Karrier Panel

KarrierPanel Barrier Wall System

KarrierPanel is a cost-effective universal barrier wall alternative solution to traditional multi-component wall systems. KarrierPanel utilizes Kingspan’s fully engineered KarrierRail to securely and safely transmit loads from a wide range of façade options to the structural supports behind the insulated panel.

KarrierPanels can now be equipped with QuadCore™ Technology, Kingspan’s next generation self-blended hybrid insulation core.

Our top-of-the-line QuadCore insulation is now an option on all KarrierPanels, in addition to the standard PIR core option.

Our KarrierPanel series:

  • Allows for faster building close-in and dry-in for reduced building costs
  • Eliminates thermal-bridging energy losses associated with standard stud/cavity insulation construction
  • Reduces delays in construction experienced with scheduling multiple trades
  • Brick Ties can also be integrated to combine the look of masonry with the benefits of an insulated metal panel
  • GREENGUARD Gold Certified
  • Certified material transparency and disclosure (QuadCore only)
  • Red List Free classification (QuadCore only)
Image

Product Information

Profile Exterior: Shadowline or flat
Interior: Shadowline
Embossing Exterior: Stucco or non-embossed
Interior: Stucco or non-embossed
Gauge Exterior: 26, 24, 22 ga
Interior: 26, 24, 22 ga
Width 24”, 30”, 36”, 40”, 42”
Thickness 2”, 2.5”, 3”, 4”, 5”, 6”
Length 8' - 53'
Reveal option ⅜" to accommodate rail
Orientation Vertical or horizontal
Post fabrication N/A
R-value ≈ 7.2 per inch per ASTM C518 @ 75˚F
≈ 8.25 per inch per ASTM C518 @ 35°F
Insulation Core R-value
QuadCore Technology ≈ 8 per inch per ASTM C518 @ 75˚F
PIR ≈ 7.2 per inch per ASTM C518 @ 75˚F
≈ 8.25 per inch per ASTM C518 @ 35°F
Test Procedure Results
Fire ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 450 or Less
CAN/ULC-S102 Flame Spread: 20 / Smoke Developed: 350 for panel with facings
CAN/ULC S127 Flame Spread: <500 for foam core
NFPA 259 Tested for potential heat of building materials
NFPA 268 Passed: Standard test method for determining ignitability of exterior wall assemblies using a radiant heat energy source
NFPA 285 Passed: Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
Structural ASTM E72 Vacuum chamber tested. Panel load / span and deflection tables are available
Thermal Transmission ASTM C518
Thermal Performance at 75°  
Thickness U-Factor R-Value
2 0.06 16.0
2.5 0.05 20.0
3 0.04 24.0
4 0.03 32.0
5 0.03 40.0
6 0.02 48.0
Air Infiltration ASTM E283 0.003 CFM/ft2 of Panel Area at 6.24 psf
Water ASTM E331 No uncontrolled water penetration at 20 psf differential pressure
AAMA 501.1 Dynamic water pressure testing – no sign of water leakage at 15 psf
Bond Strength ASTM D1623 Panels tested for tensile bond strength of metal to foam
Sample placed in an autoclave device and pressurized to 2 PSI at 212°F for 2½ hours
Skin Delamination   No skin delamination with direct pull off pressure up to 1188 psf
Test Procedure Results
Fire ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 450 or Less
CAN/ULC-S102 Flame Spread: 20 / Smoke Developed: 350 for panel with facings
CAN/ULC-S127 Flame Spread: <500 for foam core
NFPA 259 Tested for potential heat of building materials
NFPA 268 Passed: Standard test method for determining ignitability of exterior wall assemblies using a radiant heat energy source
NFPA 285 Passed: Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
Structural ASTM E72 Vacuum chamber tested. Panel load / span and deflection tables are available
Thermal Transmission ASTM C518
Thermal Performance at 75°   Thermal Performance at 35°
Thickness U-Factor R-Value Thickness U-Factor R-Value
2 0.07 14.4 2 0.06 16
2.5 0.06 18.0 2.5 0.05 20
3 0.05 21.6 3 0.04 24
4 0.03 28.8 4 0.03 32
5 0.03 36.0 5 0.03 40
6 0.02 43.2 6 0.02 48
Air Infiltration ASTM E283 0.003 CFM/ft² of Panel Area at 6.24 psf
Water ASTM E331 No uncontrolled water penetration at 20 psf differential pressure
AAMA 501.1 Dynamic water pressure testing – no sign of water leakage at 15 psf
Fatigue Tests Cyclic test to positive and negative wind loading to ± L/180 deflection The panels exceeded 2 million alternate cycles without failure or damage
Bond Strength ASTM D1623 Panels tested for tensile bond strength of metal to foam
Sample placed in an autoclave device and pressurized to 2 PSI at 212 °F for 2½ hrs
No skin delamination with direct pull off pressure up to 1188 psf

At Kingspan, we understand the unique challenges that design and construction professionals face every day.  To do our part in meeting these demands, Kingspan products are offered with our team’s guidance and technical expertise, followed up after construction is completed with our product warranties:
 

  • 2 year standard material workmanship warranty
  • Up to 20 years standard finish warranty
 
Contact our sales or customer service departments for information regarding our optional warranty programs.
 